Technical Specification Data

Dreadnought Tiles conform to BS EN 1304:2013 and should be fixed in accordance with BS 5534 "Slating and Tiling" part 1 & 2 and BS 8000 Part 6.
Frozen-Icon2 webFreeze Thaw Standards require plain clay tiles for use in the U.K. to withstand at least 150 freeze / thaw cycles under method E of European Standard EN 539-2:2013.   At Dreadnought Tiles we regard this as too low for our climate and we therefore test our tiles to withstand in excess of 400 cycles. 

Download Freeze Thaw Testing Report >>

Download this page as a pdf >>

Download Specification Word Doc for machine made and rustics >>

Download Specification Word Doc for classic tiles >>

  Tiles Classic Tiles Eaves Gable
Size 265mm x 165 mm 265mm x 165mm 215mm x 165mm 265mm x 248mm
Weight 1.19 kg 1.4kg 0.95 kg 1.8 kg
Pattern Traditional Single Camber handmade    
Material Etruria Marl Etruria Marl Etruria Marl Etruria Marl

 

  Pitched Roofs Vertical
Minimum Lap 65 mm 35 mm
Maximum Gauge 100 mm 115 mm
Approx Weight at
Maximum Gauge
71 kg/m2  for Dreadnought range
84kg/m2 for Classic range
63 kg/m2 for Dreadnought Range
72kg/m2 for Classic Range
Nails 38 x 2.65 mm alloy 38 x 2.65 mm alloy
Battens 38 x 25 mm 38 x 25 mm
Minimum Pitch 35 degree  

Quantity Guide

Tiles @ 100mm Gauge 60m2
115mm Gauge 53m2
Eaves/Tops 6/lineal metre
Gable (Tile and Half) 5/lineal metre of verge
Hips and Valleys 10/lineal metre of main rafter
Ridges Supplied in 300 mm and 450 mm lengths

Relevant Fixing Standards

BS 5534 2014 Code of Practice for Slating and Tiling
BS 8000-6.2013 Workmanship on Building Sites
BS EN 1991-1-4:2005+A1:2010 UK National Annex to Eurocode 1 -Actions on Structures - Part 1-4: General actions - wind actions